{"product_id":"high-power-4-button-remote-control-industrial-shell-learning-type-dc24v-four-way-lamp-gate-lifting-motor-controller","title":"High Power 4-Button Remote Control Industrial Shell Learning Type DC24V Four-Way Lamp Gate Lifting Motor Controller (DC24V)","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDescription:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eMultifunctional four-way wireless receiving controller\u003cbr\u003eModel: APDC-4K\u003cbr\u003eNew four-way multifunctional learning wireless controller, with newly added LED working indicator light, the working status is clear at a glance, the chip is compatible with fixed code and learning code remote controllers, and the new shell is adopted. Wiring does not need to be disassembled, and the operation is simple.\u003cbr\u003e\u003cstrong\u003e1: Technical parameters\u003c\/strong\u003e\u003cbr\u003e1 Working voltage: default DC12V (other voltages can be customized)\u003cbr\u003e2 Working current: ≤180mA\u003cbr\u003e3 Static current: ≤10mA\u003cbr\u003e4 Working temperature: -10~+70 degrees\u003cbr\u003e5 Receiving sensitivity: -109dBm\u003cbr\u003e6 Working frequency: default 315MHz (433MHz and other special frequencies can be customized)\u003cbr\u003e7 Controller size: 75.0mmX57.8.mmX20.0m\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003e2. Output mode\u003c\/strong\u003e\u003cbr\u003eAPDC-4K has four output modes: signal self-locking, signal non-locking, signal interlocking, signal non-locking and self-locking coexist.\u003cbr\u003e1. Signal self-locking: In the function selection (turn the 1 2 of the dip switch to the ON position) press the remote control A button, the relay corresponding to the A button is attracted and held, and then press the A button, the A relay is disconnected; press the remote control B button, the B button corresponding relay is attracted and held, and then press the B button, the B relay is disconnected, and the C and D buttons work in this cycle.\u003cbr\u003e2. Signal non-locking: In the function selection (keep the 1 2 of the dip switch in the 1 2 position) press the remote control A button, the relay corresponding to the A button is attracted, and the relay is disconnected after releasing; press the B button, the relay corresponding to the B button is attracted, and the relay is disconnected after releasing, and the C and D buttons work in this cycle.\u003cbr\u003e3. Signal interlock: In function selection (turn the 1 of the DIP switch to the ON position), press the A button of the remote control, and the corresponding A relay will be attracted and held; press the B button, the A relay will be disconnected, and the relay corresponding to the B button will be attracted and held. The C and D buttons will work in this cycle.\u003cbr\u003e4. Signal self-locking + non-locking: In function selection (turn the 2 of the DIP switch to the ON position), the four relays corresponding to the remote control, of which 1 and 2 are self-locking, and 3 and 4 are non-locking.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e5. Learning method: After the receiver is powered on, press the pairing button and let go when the pairing light comes on to enter the learning state. Press any button on the remote control to transmit a signal. After the receiver receives the signal, the indicator light flashes about once, indicating that the learning is successful.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e6. Code clearing method: After the receiver is powered on, press and hold the pairing button for about 10 seconds until the pairing indicator light goes out, indicating that the code clearing is successful.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003eI: Technical parameters\u003c\/strong\u003e\u003cbr\u003e1 Working voltage: DC12V\/24V\/AC220V optional (other voltages can be customized)\u003cbr\u003e2 Working current: ≤180mA\u003cbr\u003e3 Quiescent current: ≤10mA\u003cbr\u003e4 Working temperature: -10~+70 degrees\u003cbr\u003e5 Receiving sensitivity: -109dBm\u003cbr\u003e6 Working frequency: default 315MHz (433MHz and other special frequencies can be customized)\u003cbr\u003e7 Controller size: 75.0mmX57.8.mmX20.0m\u003cbr\u003e\u003cstrong\u003eII: Output mode APDC-4K has four output modes: signal self-locking, signal non-locking, signal interlocking,\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003esignal non-locking and self-locking coexistence.\u003c\/strong\u003e\u003cbr\u003e1. Signal self-locking: In the function selection (turn the 1 2 of the DIP switch to the ON position)\u003cbr\u003e, press the A button on the remote control, the relay corresponding to the A button is attracted and held, and then press the A button to disconnect the A relay; press\u003cbr\u003ethe B button on the remote control, the relay corresponding to the B button is attracted and held, and then press the B button to disconnect the B relay, and the C and D buttons\u003cbr\u003ework in this cycle.\u003cbr\u003e2. Signal non-locking: In the function selection (keep the 1 2 of the DIP switch at the 1 2 position),\u003cbr\u003epress the A button on the remote control, the relay corresponding to the A button is attracted, and the relay is disconnected after releasing; press the B button,\u003cbr\u003ethe relay corresponding to the B button is attracted, and the relay is disconnected after releasing, and the C and D buttons work in this cycle.\u003cbr\u003e3. Signal interlocking: In the function selection (turn the 1 of the DIP switch to the ON position),\u003cbr\u003epress the A button on the remote control, the corresponding A relay is attracted and held; press the B button, the A relay is disconnected, and\u003cbr\u003ethe relay corresponding to the B button is attracted and held. The C and D buttons work in this cycle.\u003cbr\u003e4. Signal self-locking + non-locking: In the function selection (turn the 2 of the dip switch to the ON position),\u003cbr\u003ethe four relays corresponding to the remote control, of which 1 and 2 are self-locking, and 3 and 4 are non-locking. Learning method:\u003cbr\u003eAfter the receiver is powered on, press the pairing key and let go when the pairing light turns on to enter the learning state. Press any key on the remote control to transmit a signal. After the receiver receives\u003cbr\u003ethe signal, the indicator light flashes about once, indicating that the learning is successful.\u003cbr\u003eClearing method: After the receiver is powered on, press and hold the pairing key for about 10 seconds until the pairing indicator light turns off, indicating that the clearing is successful.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePackage Include:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e1Set Remote controller\u003c\/p\u003e","brand":"UNIQBUY","offers":[{"title":"Default Title","offer_id":49209081692446,"sku":"BA-000047","price":2440.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/9266\/7678\/files\/21315869149_1650972874-removebg-preview_1.png?v=1727417391","url":"https:\/\/uniqbuy.in\/products\/high-power-4-button-remote-control-industrial-shell-learning-type-dc24v-four-way-lamp-gate-lifting-motor-controller","provider":"UNIQBUY","version":"1.0","type":"link"}