-
-
- Health & Beauty
- General Products
- Electronics
- Smart Device Accessories
- Sports & Outdoors
- Fashion
- Personal Needs
- IC for iPhone
- Watch Accessories
- Others
- Home
- Wood Working Tools
- Spot Welding Machine Control Panel Double Pulse Convenient - 2 Spot Welding Machine Control Panel Double Pulse Convenient - 2
- Description
One set of spot welding machine control panel is powerful to use which can meet your accuracy needs.Features:The new motherboard adds a plastics base which makes it easier to install. The panel is made of a snap-on plastics surface. No screw tip is left after installation.Fine quality needle type glue filling transformer is used for motherboard power supply which can protect collision damage during transportation and has fine moisture resistance. Direct welding on motherboard also makes installation easier.Supporting the production of a mask so that you can also make the factory machine in the amateur conditions.The parameters of the power down parameter are stored and the parameters used during the last shutdown of the machine are read.The output power regulation is linearized. The new version divides the output power by 100 equal parts.The output of spot welding signal is increased. When the spot welding switch is pressed the optocoupler is turned on. When the welding is finished the optocoupler is closed after a certain delay (settable). The optocoupler can be used as feedback signal of automatic spot welding machine.One Set include a motherboard one display panel a patch and one 400mm long 5P and one 2P lines.Specifications:Motherboard Size: 115 * 90 * 55mm / 4.5 * 3.5 * 2.2inMotherboard Weight: 184g / 6.5ounceDisplay Panel Size: 100 * 45 * 20mm / 3.9 * 1.8 * 0.8inDisplay Panel Weight: 32g / 1.1ouncePatch Size: 115 * 60mm / 4.5 * 2.4inPatch Weight: 2g / 0.1ounce5P Lines Length: 400mm / 15.7in5P Lines Weight: 8g / 0.3ounce2P Lines Length: 400mm / 15.7in2P Lines Weight: 4g / 0.1ouncePackage size: 145 * 110 * 85mm / 5.7 * 4.3 * 3.3inPackage Weight: 295g / 10.4ounceParameter Tuning:The first spot welding time:Adjustable range 1-99 AC cycle (for safety the board default maximum is 20 if more than 20 see the maximum limit section later self-change).Press the Settings button when the Time 1 indicator light is on the digital tube begins to flicker press the Add or Reduce button to the desired value and press the Settings button again to save and exit.The first spot welding current:Adjustable range 25%-99% adjust the percentage of output power relative to full power (default maximum value is 99 if you need other values see the Maximum Limit section later change by yourself).Press the Settings button when the Current 1 indicator light is on the digital tube begins to flicker press the Add or Reduce button to the desired value and then press the Settings button to save and exit.The first and second spot welding intervals:Adjustable range 1-99 AC half cycle that is the value multiplied by 10 milliseconds (board default maximum value is 25 if more than 25 see the maximum limit section later self-change).Press the Settings button when the Interval indicator lights up the digital tube begins to flicker press the Add or Reduce button to the desired value and then press the Settings button to save and exit.Second spot welding time:Adjustable range of 0-99 AC cycle (for safety the board default maximum value is 20 if more than 20 see the maximum limit section later self-change)When this time is set to 0 it operates in the state of monopulse.Press the Settings button when the Time 2 indicator lights up the digital tube begins to flicker press the Add or Reduce button to the desired value and then press the Settings button to save and exit.Second spot welding current:Adjustable range 25%-99% adjust the percentage of output power relative to full power (default maximum value is 99 if you need other values see the Maximum Limit section later change by yourself).Press the Settings button when the Current 2 indicator light is on the digital tube begins to flicker press the Add or Reduce button to the desired value and then press the Settings button to save and exit.Parameter storage and transferThe machine automatically records the last parameters when it is turned off and automatically loads it on the next boot.At the same time the machine can store 5 sets of common parameter settings.A The number of the current parameter is displayed when the parameter indicator is lit and the number is 0 if the current parameter is boot load parameter or if the parameter has been modified.B Press the Settings key enter the selection of loading and storage parameters press the Increase or Decrease button to display the Ld and SA respectively indicating that the subsequent operations are loaded or stored and press the Settings button when the Ld is displayed and if the storage parameters are needed when the SA is displayed. Press the settings button.C Connect the item then display the number of parameters press the add or subtract button the display screen changes from 1 to 5 respectively representing the parameters of five items select the entry number needed to be stored or transferred press the set key to achieve loading or storage.Maximum limit:Because spot welding transformer is usually made by hand power wire diameter turns are not the same resulting in large parameter dispersion controller to adapt to a variety of transformers the adjustable range of parameters is very large very likely due to improper settings lead to cell damage (I have due to spot welding time adjustment for too long so that the cell surface was burned through. So it is necessary to limit the maximum value of each parameter. This machine has the function of limiting the maximum value of parameters.The setting method is as follows:1. Press the Add or Subtract button to make the Parameter indicator light on then press the Settings button not to let go about 5 seconds into the upper limit setting function when the Time 1 indicator flashes while the digital tube shows the current spot welding time 1 upper limit.2. Press the increase or decrease keys time 1 current 1 interval time 2 current 2 indicator lights flicker in turn and display their respective upper limits select the parameters needed to set press the set key at this time the digital tube flickers press the increase or decrease key to change the limit value adjust to After pressing the setting button the display will stop flashing and the setting of the current parameter is completed.3. After setting the limits you need to save them to take effect. The method is to press the subtraction button to make the parameters indicator flashing the digital tube shows SA and the settings button which completes the saving. If you do not want to save you can not operate the button for 5 seconds the system will exit the settings function and discard the previously modified parameters. If it is not saved all settings are invalid and the control board is still running according to the original limit value.The use of signal output:The control board is equipped with the output of spot welding signal. When the spot welding switch is pressed the optocoupler is turned on. When the welding is finished the optocoupler is closed after a certain delay (which can be set). It can be used as the feedback signal of automatic spot welding machine. The signal is synchronized with the LED indicator on the board. The delay time is set as follows:Press the subtraction button to make the parameter indicator light on. Pressing the setting button will go into the upper limit setting state but do not let go until the digital tube shows the value and flicker. The value displayed at this time is the delay time of the signal output after spot welding. The half-cycle meter displays 10 which means the optical coupling. The 100MS will be closed after the spot welding is completed with reference to the indicator on the board both of which are synchronous.Package List:1 * Motherboard1 * Display Panel1 * Patch1 * 400mm Long 5P lines1 * 400mm Long 2P lines